The tripple-no that make the CPA202 a new paradigm in Reaction Calorimetry

This is what no-no-no stands for by practical advantages:
No for no additional information needed.
No for no baseline to be guessed. Calorimeter 202 measures all significant heat flow, that leaves or enter the system.
No for no calibration curve to be estimated. Calorimeter 202 relies on independent, pre-calibrated and true heat flow measurements.
Calorimeter 202 represents the State of the Art in calorimetry – telling the truth, the whole truth and nothing but the truth.
The CPA202, is a True Heat Flow Reaction Calorimeter. The small reactor volume makes it the natural choice especially when working with expensive or energetic chemicals.

More Info

 

Download complete prod info CPA202.pdf

 

The precalibrated and ready to use CPA 102 and CPA 122
- reveal a new and improved standard in Reaction Calorimetry


Compared to traditional reaction calorimeters the CPA102 and the CPA122 systems are precalibrated and ready to use whenever needed. ChemiSens’ 100-range cover the needs in most laboratory situations – from small size reactors for general laboratory work to small
scale laboratory production.

More info CPA 102

More info CPA 122

Download complete prod info CPA102 /122.pdf

The main support units VRC202 – the universal dosing controller

The VRC202 is the general interface between auxiliary sensors/dosing devices and the CPA202 or CPA 102 and 122 control units.

Virtually any type of auxiliary sensor/transducer or dosing device can be installed.

Sensors/transducers
Pressure
• pH or other electrodes
•Thermal mass flow sensor for gas or liquid
•Temperature sensor – Pt100 sensor
•General sensors with voltage, mV or mA output signals
•Balances via RS 232 communication

Dosing devices
•Any type of pump/dosing device that accept standard control signals such as Volt or mA or frequency or pulse width modulation.
•Solenoid valves
•Thermal mass flow controllers
•Intelligent dosing devices controlled via RS232 communication


Download PDF

 

The MSC202 Syringe Dosing Pump
The MSC 202 is designed to give low flow rates that are pulse free, accurate and stable. The operating principle is “one shot” syringe. The syringe pump has an open flow line all the way during the dosing phase. Highly viscous materials as well as emulsions and suspensions can be dosed. The unit is designed to work with all ChemiSens calorimeters.

The MSC202 package
One control unit
Two separate motor syringes
The necessary cables


Download PDF